A vortex meter primary flow element produces a series of oscillations of pressure. Generally the physical property generated by the primary flow element is more convenient to measure than the flow itself. The properties of the primary flow element, and the fidelity
of the practical installation to the assumptions made in calibration, are critical factors in the accuracy of the flow measurement
A positive displacement meter may be compared to a bucket and a stopwatch. The stopwatch is started when the flow starts, and stopped when the bucket reaches its limit. The volume divided by the time gives the flow rate. For continuous measurements, we need a system of continually filling and emptying buckets to divide the flow without letting it out of the pipe.
Flow meter
تجهیز صنعت وارد کننده انواع فلومتر آلتراسونیکUltrasonic Flow meter، فلومتر الکترومغناطیسی Electromagnetic Flow meter ،فلومتر ورتکس Vortex Flow meter- مس فلومتر Mass Flow meter – انواع فلومتر آب و گاز با برندهای اندرس هازر ، کرونه ، یوکوگاوا از سایز “1/2 تا “16
فلومتر
تامین تجهیزات صنایع نفت ،گاز و پتروشیمی واردات و تامین انواع فلومتر
فلومتر Flow meterچیست؟
امروزه اندازه گیری جریان سیال بعنوان یکی از مهمترین پارامترهای اندازه گیری در صنایع از اهمیت ویژه ای برخوردار است.
در حقیقت اغلب کارشناسان پس از اندازه گیری دما مهمترین کمیت اندازه گیری در صنایع را فلو یا جریان سیال میدانند.با توجه به اهمیت اندازه گیری این کمیت و همچنین تنوع فرآیند صنایع گوناگون ، در طول زمان روشهای مختلفی برای اندازه گیری جریان سیال بوجود آمده است.انتخاب Flow meter مناسب برای هر کاربرد نیاز به دانش کلی نسبت به روشهای گوناگون فلومتری و در نظر داشتن پارامترهای اصلی اندازه گیری از قبیل دقت،قیمت تمام شده،هزینه های تعمیرات و کالیبراسیون، سازگاری عملکرد Flow meter با شرایط پروسه تولیدو…می باشد.
تکنیکنهای مختلفی برای اندازه گیری فلو به کار میرود که میتوان به مواردی همچون
اندازه گیری جریان به روش جابجائی مثبت Positive Displacement
اندازه گیری جریان به روش اوریفیس پلیت Orifice Plate
اندازه گیری جریان به روش توربینی Turbine
اندازه گیری جریان به روتامتری (variable area)
اندازه گیری جریان به آلتراسونیک با پدیده دوپلر Ultrasonic: Doppler
اندازه گیری جریان به آلتراسونیک با روش زمان انتقال و …. Ultrasonic: Transit Time, Time of Travel, Time of Flight
اندازه گیری جریان به ونتوری Orifice Plate
اندازه گیری جریان به مغناطیسی Magnetic
اندازه گیری جریان به ورتکس Vortex Shedder
اندازه گیری جریان به روتامتر) Variable Area (Rota meter
اندازه گیری جریان به فلومتر مخصوص کانالهای باز Weir and Flume Open channel
اندازه گیری جریان به کوریالیس Coriolis
اندازه گیری جریان به گرمائی Thermal
اندازه گیری جریان به پیتوت Pitot Tube
اشاره کرد.
کمپانی HACH با ایجاد راهکارهای قابل اطمینان و آسان به کیفیت آب در سراسر جهان کمک می کند .شرکت HACHاز زمان تاسیس خود در سال 1933 همواره در حال توسعه راه حل های نو آورانه برای بهبود کیفیت آب بوده است . امروزه محصولات شرکت HACH در سراسر جهان یافت می شود . Hach به عنوان یک شرکت مجهز به پشتیبانی و منابع برای ارایه محصولات پیشرفته وراهنمای تخصصی است که شما انتظار دارید. به دلیل کیفیت بالای محصولات ارائه شده توسط شرکت hach، متخصصین در سراسر جهان برای اندازهگیری pH، هدایت،DO (Dissolved Oxygen) ، کدورت، BOD (Biochemical Oxygen Demand)، اسپکتروفتومتر، غلظت یون و … از محصولات این کمپانی استفاده میکنند.
محصولات این شرکت عبارت از
کد | شرح | واحد |
2242000 | Aluminium Reagent Set, Powder Pillows, 0.008-0.800mg/L Al | 1ST |
2254069 | Amino Acid F Reagent Powder Pillows, 10 mL, pk/100 Silica low range include 2459300 = 2254069 + 2106269 + 199526 | 100 test |
2653199 | Ammonia Cyanurate Reagent Powder Pillows (100 pcs.) | |
2668000 | Ammonia Reagent Set, Powder Pillows, 0.01-0.50 mg/L NH3-N 2653199+2653299 | 1ST |
2653299 | Ammonia Salicylate Reagent Powder Pillows | |
1206499 | Barium Reagent Powder Pillows, 2-100mg/L Ba | 1ST |
45249 | Buffer solution, sulfate type, 500mL | 500ml |
2444400 | Chlorine (Total) Test Kit, Model CN-21P | |
1271099 | Chromium Reagent Powder Pillows, 0.010-0.700mg/L Cr6+ | 1ST |
2106269 | Citric Acid Reagent Powder Pillows for Silica, 10 mL, pk/100 Silica low range include2459300 = 2254069 + 2106269 + 199526 | 100 test |
2125951 | COD TNT, 0 - 1500 mg/L O2 | 1ST |
2415951 | COD TNT, 0 - 15000 mg/L O2 | 1ST |
2105869 | CUVER 1 COPPER REAGENT FOR 10ML SAMPLE 1 * 100 it | 100 Tests |
24302000 | Cyanide Reagent Set, CyaniVer, 10 mL-22430200 = 2106869 + 2106969 + 2107069 | 100test |
2106869 | CyaniVer 3 Cyanide Reagent Powder Pillows, 10 mL, pk/100 Cyanide Reagent Set, CyaniVer, 10-mL 2430200 = 2106869 + 2106969 + 2107069 | 100 test |
2446600 | DEHA REAGENT 1 1 * 100 it :2167969-DEHA REAGENT 2 1 * 100 ml:2168042 | 100ml + 100test |
2167969 | DEHA Reagent 1 Powder Pillows, pk/100 | 100test |
2168042 | DEHA Reagent 2 Solution, 100 mL | 100ml |
2168049 | DEHA Reagent 2 Solution, 500 mL | 500ml |
100868 | Detergenzien Reagenz Pulverkissen 25 St. 1 * 25 ST Detergents Reagent Set 2446800 = 45249 + 100868 + benzene ACS | 25 Tests |
100868 | Detergenzien Reagenz Pulverkissen 25 St. 1 * 25 ST Detergents Reagent Set 2446800 = 45249 + 100868 + benzene ACS | 25 Tests |
DR 2800 | DR 2800 | 1st |
51935220000% | ELECTRODE PH GEL W/TEMP BNC/DIN 1 * 1 item | 1st |
103769 | FERROUS IRON REAGENT 1 * 100 it | st |
2105769 | FERROVER IRON REAGENT FOR 10ML SAMPLE 1* 100 it | 100 Tests |
230149 | FERROZINE IRON REAGENT SOLUTION 1 * 500ml | 500ml |
2125951 | Hach Digestion Solution for COD 0-1500ppm 1 * 25 ite | 25 Tests |
42449 | Hardness 1 Buffer solution, pH 10.1 1 *1 item | 1st |
2429800 | Low range Nitrate reagent Set 1 * 100 it 2429800 = 2107249 + 2107169 | 100 Test |
2651700 | Manganese Reagent Set, PAN, 0.006-0.700mg/L Mn | 1ST |
199526 | Molybdate 3 Reagent Solution, 50 mL SCDB Silica low range include 2459300= 2254069 + 2106269 + 199526 | 50ml |
2106169 | NITRAVER 5 NITRATE REAG. FOR 10ML SAMPLE 1 * 100 it | 100 Tests |
2106169 | NITRAVER 5 NITRATE REAG. FOR 10ML SAMPLE 1 * 100 it | 100 Tests |
2107169 | NitriVer 3 Nitrite Reagent Powder pillows 1 * 100 it | 100 Test |
2714100 | Nitrogen, total, TNT, 10-150mg/L N (2714045+2672145) | |
183699 | Phenol 2 Regent Power Pilows 1 * 100 it 0.002-0.2mg/L ( 2243900 = 193699 +42449 + 87299 + Chloroform 4L) | 100 Tests |
87299 | Phenol Regent Power Pilows 1 * 100 it | 100 Tests |
2106069 | PHOSVER 3 PHOSFATE REAG. FOR 10ML SAMPLE 1 * 100 ST | |
2106069 | PHOSVER 3 PHOSFATE REAG. FOR 10ML SAMPLE 1 * 100 ST | |
2603649 | Porphyrin 2 Reagent Powder Pillows | |
2106269 | Powder Pillows Citric Acid Reagent for Silica (10ml Sample Size) 1 * 100 it | 100 Tests |
2106269 | Powder Pillows Citric Acid Reagent for Silica (10ml Sample Size) 1 * 100 it | 100 Tests |
2106969 | Powder Pillows CyaniVer 4 Cyanide Reagent (10ml Sample Size) 1 * 100 it Cyanide Reagent Set, CyaniVer, 10-mL 2430200 = 2106869 + 2106969 + 2107069 | 100 Test |
2107069 | Powder Pillows CyaniVer 5 Cyanide Reagent (10ml Sample Size) 1 * 100 it Cyanide Reagent Set, CyaniVer, 10-mL 2430200 = 2106869 + 2106969 + 2107069 | 100 test |
2105569 | Powder Pillows DPD Free Chlorine Reagent (10ml Sample Size) 1 * 1.00 | 100 Tests |
1407799 | Powder Pillows DPD Free Chlorine Reagent (5ml Sample Size) | 100test |
1403499 | Powder Pillows NitraVer 5 Nitrate Reagent (25ml Sample Size) 1 * 100 it | 100test |
221969 | Powder Pillows NitriVer 2 Nitrite Reagent (25ml Sample Size) 1 * 100 it | 100test |
1406599 | Powder Pillows NitriVer 3 Nitrite Reagent (25ml Sample Size) 1 * 100 it | 100test |
2319800 | REAGENT SET CHLORIDE 0.1-25.0MG/L 1 * 50 Tes(22121-22122) | |
2651700 | REAGENT SET MANGANESE PAN METHOD 1 * 50Tes 2651700 = 2122326 + 1457799 + 2122426 | 50 test |
2458200 | REAGENT SET NITROGEN AMMONIA NESSLER 1 * 1 SET include = 2376526 + 2376626 + 2119449 | 100 test |
2429600 | REAGENT SET SILICA HR 0-100MG/L 1 * 1 set include = 2107469 + 2106269 + 2107369 | 100 test |
2459300 | Reagent Set Silica Low Range 0.01-1.6mg/l SiO2 1 * 1 00 Silica low range include = 2254069 + 2106269 + 199526 | 100 test |
2612602 | SAMPLE CELL FOR DR/4000 1 item | 1 item |
2084900 | SAMPLE CELLS FOR RATIO TURBIDIMETER 1 *6 item | |
245032 | Sodium Hydroxide Standard Solution, 5.0 N, 100 mL MDB for determination total phosphate = 244932+245032+2106069 Multi-purpose sodium hydroxide solution. Used for sample digestions and pH adjustments. 100 mL Marked Dropping Bottle | 100ml |
44449 | SPADNS REAGENT FLUORIDE | 500ml |
44453 | SPADNS REAGENT FLUORIDE | 1L |
2660642 | STABLCAL SOLUTION 1000 NTU 1 * 100 ml | 100 ml |
2106769 | SULFAVER 4 SULFATE REAG. POWDER PILLOWS1 * 100 it | 100 Tests |
244932 | Sulfuric Acid Standard Solution, 5.25 N, 100 mL for determination total phosphate = 244932+245032+2106069 Multi-purpose sulfuric acid standard solution. Used for sample digestions and pH adjustments. 100 mL Marked Dropping Bottle | 100ml |
HPT430 | SULPHITE 0.1-5.0 mg/L | |
2672145 | TN Acid reagent C solution | 1st |
2714045 | TN Hydroxyde reagent solution | 1st |
2671745 | TNT, TN HYDROXIDE RGT PK/50 nn TNT, TN HYDROXIDE RGT PK/50 | 1st |
2125716 | ZERO STANDARD 1 * 1 l | 1L |